ANBZ: #5366
commit 47c29d6921 upstream.
[ Upstream commit 47c29d6921 ]
In bq24190_probe, &bdi->input_current_limit_work is bound
with bq24190_input_current_limit_work. When external power
changed, it will call bq24190_charger_external_power_changed
to start the work.
If we remove the module which will call bq24190_remove to make
cleanup, there may be a unfinished work. The possible
sequence is as follows:
CPU0 CPUc1
|bq24190_input_current_limit_work
bq24190_remove |
power_supply_unregister |
device_unregister |
power_supply_dev_release|
kfree(psy) |
|
| power_supply_get_property_from_supplier
| //use
Fix it by finishing the work before cleanup in the bq24190_remove
Fixes: 9777467257 ("power_supply: Initialize changed_work before calling device_add")
Signed-off-by: Zheng Wang <zyytlz.wz@163.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
[Fixes conflicts]
Fixes: CVE-2023-33288
Signed-off-by: Qiao Ma <mqaio@linux.alibaba.com>
Signed-off-by: Xiao Long <xiaolong@openanolis.org>
Reviewed-by: Xunlei Pang <xlpang@linux.alibaba.com>
Link: https://gitee.com/anolis/cloud-kernel/pulls/1789