forked from OSchip/llvm-project
				
			
		
			
				
	
	
		
			348 lines
		
	
	
		
			12 KiB
		
	
	
	
		
			C++
		
	
	
	
			
		
		
	
	
			348 lines
		
	
	
		
			12 KiB
		
	
	
	
		
			C++
		
	
	
	
| //===-- xray_interface.cpp --------------------------------------*- C++ -*-===//
 | |
| //
 | |
| //                     The LLVM Compiler Infrastructure
 | |
| //
 | |
| // This file is distributed under the University of Illinois Open Source
 | |
| // License. See LICENSE.TXT for details.
 | |
| //
 | |
| //===----------------------------------------------------------------------===//
 | |
| //
 | |
| // This file is a part of XRay, a dynamic runtime instrumentation system.
 | |
| //
 | |
| // Implementation of the API functions.
 | |
| //
 | |
| //===----------------------------------------------------------------------===//
 | |
| 
 | |
| #include "xray_interface_internal.h"
 | |
| 
 | |
| #include <cstdint>
 | |
| #include <cstdio>
 | |
| #include <errno.h>
 | |
| #include <limits>
 | |
| #include <sys/mman.h>
 | |
| 
 | |
| #include "sanitizer_common/sanitizer_common.h"
 | |
| #include "xray_defs.h"
 | |
| 
 | |
| namespace __xray {
 | |
| 
 | |
| #if defined(__x86_64__)
 | |
| // FIXME: The actual length is 11 bytes. Why was length 12 passed to mprotect()
 | |
| // ?
 | |
| static const int16_t cSledLength = 12;
 | |
| #elif defined(__aarch64__)
 | |
| static const int16_t cSledLength = 32;
 | |
| #elif defined(__arm__)
 | |
| static const int16_t cSledLength = 28;
 | |
| #elif SANITIZER_MIPS32
 | |
| static const int16_t cSledLength = 48;
 | |
| #elif SANITIZER_MIPS64
 | |
| static const int16_t cSledLength = 64;
 | |
| #elif defined(__powerpc64__)
 | |
| static const int16_t cSledLength = 8;
 | |
| #else
 | |
| #error "Unsupported CPU Architecture"
 | |
| #endif /* CPU architecture */
 | |
| 
 | |
| // This is the function to call when we encounter the entry or exit sleds.
 | |
| __sanitizer::atomic_uintptr_t XRayPatchedFunction{0};
 | |
| 
 | |
| // This is the function to call from the arg1-enabled sleds/trampolines.
 | |
| __sanitizer::atomic_uintptr_t XRayArgLogger{0};
 | |
| 
 | |
| // This is the function to call when we encounter a custom event log call.
 | |
| __sanitizer::atomic_uintptr_t XRayPatchedCustomEvent{0};
 | |
| 
 | |
| // MProtectHelper is an RAII wrapper for calls to mprotect(...) that will undo
 | |
| // any successful mprotect(...) changes. This is used to make a page writeable
 | |
| // and executable, and upon destruction if it was successful in doing so returns
 | |
| // the page into a read-only and executable page.
 | |
| //
 | |
| // This is only used specifically for runtime-patching of the XRay
 | |
| // instrumentation points. This assumes that the executable pages are originally
 | |
| // read-and-execute only.
 | |
| class MProtectHelper {
 | |
|   void *PageAlignedAddr;
 | |
|   std::size_t MProtectLen;
 | |
|   bool MustCleanup;
 | |
| 
 | |
| public:
 | |
|   explicit MProtectHelper(void *PageAlignedAddr,
 | |
|                           std::size_t MProtectLen) XRAY_NEVER_INSTRUMENT
 | |
|       : PageAlignedAddr(PageAlignedAddr),
 | |
|         MProtectLen(MProtectLen),
 | |
|         MustCleanup(false) {}
 | |
| 
 | |
|   int MakeWriteable() XRAY_NEVER_INSTRUMENT {
 | |
|     auto R = mprotect(PageAlignedAddr, MProtectLen,
 | |
|                       PROT_READ | PROT_WRITE | PROT_EXEC);
 | |
|     if (R != -1)
 | |
|       MustCleanup = true;
 | |
|     return R;
 | |
|   }
 | |
| 
 | |
|   ~MProtectHelper() XRAY_NEVER_INSTRUMENT {
 | |
|     if (MustCleanup) {
 | |
|       mprotect(PageAlignedAddr, MProtectLen, PROT_READ | PROT_EXEC);
 | |
|     }
 | |
|   }
 | |
| };
 | |
| 
 | |
| } // namespace __xray
 | |
| 
 | |
| extern __sanitizer::SpinMutex XRayInstrMapMutex;
 | |
| extern __sanitizer::atomic_uint8_t XRayInitialized;
 | |
| extern __xray::XRaySledMap XRayInstrMap;
 | |
| 
 | |
| int __xray_set_handler(void (*entry)(int32_t,
 | |
|                                      XRayEntryType)) XRAY_NEVER_INSTRUMENT {
 | |
|   if (__sanitizer::atomic_load(&XRayInitialized,
 | |
|                                __sanitizer::memory_order_acquire)) {
 | |
| 
 | |
|     __sanitizer::atomic_store(&__xray::XRayPatchedFunction,
 | |
|                               reinterpret_cast<uintptr_t>(entry),
 | |
|                               __sanitizer::memory_order_release);
 | |
|     return 1;
 | |
|   }
 | |
|   return 0;
 | |
| }
 | |
| 
 | |
| int __xray_set_customevent_handler(void (*entry)(void *, size_t))
 | |
|     XRAY_NEVER_INSTRUMENT {
 | |
|   if (__sanitizer::atomic_load(&XRayInitialized,
 | |
|                                __sanitizer::memory_order_acquire)) {
 | |
|     __sanitizer::atomic_store(&__xray::XRayPatchedCustomEvent,
 | |
|                               reinterpret_cast<uintptr_t>(entry),
 | |
|                               __sanitizer::memory_order_release);
 | |
|     return 1;
 | |
|   }
 | |
|   return 0;
 | |
| }
 | |
| 
 | |
| 
 | |
| int __xray_remove_handler() XRAY_NEVER_INSTRUMENT {
 | |
|   return __xray_set_handler(nullptr);
 | |
| }
 | |
| 
 | |
| int __xray_remove_customevent_handler() XRAY_NEVER_INSTRUMENT {
 | |
|   return __xray_set_customevent_handler(nullptr);
 | |
| }
 | |
| 
 | |
| __sanitizer::atomic_uint8_t XRayPatching{0};
 | |
| 
 | |
| using namespace __xray;
 | |
| 
 | |
| // FIXME: Figure out whether we can move this class to sanitizer_common instead
 | |
| // as a generic "scope guard".
 | |
| template <class Function> class CleanupInvoker {
 | |
|   Function Fn;
 | |
| 
 | |
| public:
 | |
|   explicit CleanupInvoker(Function Fn) XRAY_NEVER_INSTRUMENT : Fn(Fn) {}
 | |
|   CleanupInvoker(const CleanupInvoker &) XRAY_NEVER_INSTRUMENT = default;
 | |
|   CleanupInvoker(CleanupInvoker &&) XRAY_NEVER_INSTRUMENT = default;
 | |
|   CleanupInvoker &
 | |
|   operator=(const CleanupInvoker &) XRAY_NEVER_INSTRUMENT = delete;
 | |
|   CleanupInvoker &operator=(CleanupInvoker &&) XRAY_NEVER_INSTRUMENT = delete;
 | |
|   ~CleanupInvoker() XRAY_NEVER_INSTRUMENT { Fn(); }
 | |
| };
 | |
| 
 | |
| template <class Function>
 | |
| CleanupInvoker<Function> scopeCleanup(Function Fn) XRAY_NEVER_INSTRUMENT {
 | |
|   return CleanupInvoker<Function>{Fn};
 | |
| }
 | |
| 
 | |
| inline bool patchSled(const XRaySledEntry &Sled, bool Enable,
 | |
|                       int32_t FuncId) XRAY_NEVER_INSTRUMENT {
 | |
|   // While we're here, we should patch the nop sled. To do that we mprotect
 | |
|   // the page containing the function to be writeable.
 | |
|   const uint64_t PageSize = GetPageSizeCached();
 | |
|   void *PageAlignedAddr =
 | |
|       reinterpret_cast<void *>(Sled.Address & ~(PageSize - 1));
 | |
|   std::size_t MProtectLen = (Sled.Address + cSledLength) -
 | |
|                             reinterpret_cast<uint64_t>(PageAlignedAddr);
 | |
|   MProtectHelper Protector(PageAlignedAddr, MProtectLen);
 | |
|   if (Protector.MakeWriteable() == -1) {
 | |
|     printf("Failed mprotect: %d\n", errno);
 | |
|     return XRayPatchingStatus::FAILED;
 | |
|   }
 | |
| 
 | |
|   bool Success = false;
 | |
|   switch (Sled.Kind) {
 | |
|   case XRayEntryType::ENTRY:
 | |
|     Success = patchFunctionEntry(Enable, FuncId, Sled, __xray_FunctionEntry);
 | |
|     break;
 | |
|   case XRayEntryType::EXIT:
 | |
|     Success = patchFunctionExit(Enable, FuncId, Sled);
 | |
|     break;
 | |
|   case XRayEntryType::TAIL:
 | |
|     Success = patchFunctionTailExit(Enable, FuncId, Sled);
 | |
|     break;
 | |
|   case XRayEntryType::LOG_ARGS_ENTRY:
 | |
|     Success = patchFunctionEntry(Enable, FuncId, Sled, __xray_ArgLoggerEntry);
 | |
|     break;
 | |
|   case XRayEntryType::CUSTOM_EVENT:
 | |
|     Success = patchCustomEvent(Enable, FuncId, Sled);
 | |
|     break;
 | |
|   default:
 | |
|     Report("Unsupported sled kind '%d' @%04x\n", Sled.Address, int(Sled.Kind));
 | |
|     return false;
 | |
|   }
 | |
|   return Success;
 | |
| }
 | |
| 
 | |
| // controlPatching implements the common internals of the patching/unpatching
 | |
| // implementation. |Enable| defines whether we're enabling or disabling the
 | |
| // runtime XRay instrumentation.
 | |
| XRayPatchingStatus controlPatching(bool Enable) XRAY_NEVER_INSTRUMENT {
 | |
|   if (!__sanitizer::atomic_load(&XRayInitialized,
 | |
|                                 __sanitizer::memory_order_acquire))
 | |
|     return XRayPatchingStatus::NOT_INITIALIZED; // Not initialized.
 | |
| 
 | |
|   uint8_t NotPatching = false;
 | |
|   if (!__sanitizer::atomic_compare_exchange_strong(
 | |
|           &XRayPatching, &NotPatching, true, __sanitizer::memory_order_acq_rel))
 | |
|     return XRayPatchingStatus::ONGOING; // Already patching.
 | |
| 
 | |
|   uint8_t PatchingSuccess = false;
 | |
|   auto XRayPatchingStatusResetter = scopeCleanup([&PatchingSuccess] {
 | |
|     if (!PatchingSuccess)
 | |
|       __sanitizer::atomic_store(&XRayPatching, false,
 | |
|                                 __sanitizer::memory_order_release);
 | |
|   });
 | |
| 
 | |
|   // Step 1: Compute the function id, as a unique identifier per function in the
 | |
|   // instrumentation map.
 | |
|   XRaySledMap InstrMap;
 | |
|   {
 | |
|     __sanitizer::SpinMutexLock Guard(&XRayInstrMapMutex);
 | |
|     InstrMap = XRayInstrMap;
 | |
|   }
 | |
|   if (InstrMap.Entries == 0)
 | |
|     return XRayPatchingStatus::NOT_INITIALIZED;
 | |
| 
 | |
|   const uint64_t PageSize = GetPageSizeCached();
 | |
|   if ((PageSize == 0) || ((PageSize & (PageSize - 1)) != 0)) {
 | |
|     Report("System page size is not a power of two: %lld\n", PageSize);
 | |
|     return XRayPatchingStatus::FAILED;
 | |
|   }
 | |
| 
 | |
|   uint32_t FuncId = 1;
 | |
|   uint64_t CurFun = 0;
 | |
|   for (std::size_t I = 0; I < InstrMap.Entries; I++) {
 | |
|     auto Sled = InstrMap.Sleds[I];
 | |
|     auto F = Sled.Function;
 | |
|     if (CurFun == 0)
 | |
|       CurFun = F;
 | |
|     if (F != CurFun) {
 | |
|       ++FuncId;
 | |
|       CurFun = F;
 | |
|     }
 | |
|     patchSled(Sled, Enable, FuncId);
 | |
|   }
 | |
|   __sanitizer::atomic_store(&XRayPatching, false,
 | |
|                             __sanitizer::memory_order_release);
 | |
|   PatchingSuccess = true;
 | |
|   return XRayPatchingStatus::SUCCESS;
 | |
| }
 | |
| 
 | |
| XRayPatchingStatus __xray_patch() XRAY_NEVER_INSTRUMENT {
 | |
|   return controlPatching(true);
 | |
| }
 | |
| 
 | |
| XRayPatchingStatus __xray_unpatch() XRAY_NEVER_INSTRUMENT {
 | |
|   return controlPatching(false);
 | |
| }
 | |
| 
 | |
| XRayPatchingStatus patchFunction(int32_t FuncId,
 | |
|                                  bool Enable) XRAY_NEVER_INSTRUMENT {
 | |
|   if (!__sanitizer::atomic_load(&XRayInitialized,
 | |
|                                 __sanitizer::memory_order_acquire))
 | |
|     return XRayPatchingStatus::NOT_INITIALIZED; // Not initialized.
 | |
| 
 | |
|   uint8_t NotPatching = false;
 | |
|   if (!__sanitizer::atomic_compare_exchange_strong(
 | |
|           &XRayPatching, &NotPatching, true, __sanitizer::memory_order_acq_rel))
 | |
|     return XRayPatchingStatus::ONGOING; // Already patching.
 | |
| 
 | |
|   // Next, we look for the function index.
 | |
|   XRaySledMap InstrMap;
 | |
|   {
 | |
|     __sanitizer::SpinMutexLock Guard(&XRayInstrMapMutex);
 | |
|     InstrMap = XRayInstrMap;
 | |
|   }
 | |
| 
 | |
|   // If we don't have an index, we can't patch individual functions.
 | |
|   if (InstrMap.Functions == 0)
 | |
|     return XRayPatchingStatus::NOT_INITIALIZED;
 | |
| 
 | |
|   // FuncId must be a positive number, less than the number of functions
 | |
|   // instrumented.
 | |
|   if (FuncId <= 0 || static_cast<size_t>(FuncId) > InstrMap.Functions) {
 | |
|     Report("Invalid function id provided: %d\n", FuncId);
 | |
|     return XRayPatchingStatus::FAILED;
 | |
|   }
 | |
| 
 | |
|   // Now we patch ths sleds for this specific function.
 | |
|   auto SledRange = InstrMap.SledsIndex[FuncId - 1];
 | |
|   auto *f = SledRange.Begin;
 | |
|   auto *e = SledRange.End;
 | |
| 
 | |
|   bool SucceedOnce = false;
 | |
|   while (f != e)
 | |
|     SucceedOnce |= patchSled(*f++, Enable, FuncId);
 | |
| 
 | |
|   __sanitizer::atomic_store(&XRayPatching, false,
 | |
|                             __sanitizer::memory_order_release);
 | |
| 
 | |
|   if (!SucceedOnce) {
 | |
|     Report("Failed patching any sled for function '%d'.", FuncId);
 | |
|     return XRayPatchingStatus::FAILED;
 | |
|   }
 | |
| 
 | |
|   return XRayPatchingStatus::SUCCESS;
 | |
| }
 | |
| 
 | |
| XRayPatchingStatus __xray_patch_function(int32_t FuncId) XRAY_NEVER_INSTRUMENT {
 | |
|   return patchFunction(FuncId, true);
 | |
| }
 | |
| 
 | |
| XRayPatchingStatus
 | |
| __xray_unpatch_function(int32_t FuncId) XRAY_NEVER_INSTRUMENT {
 | |
|   return patchFunction(FuncId, false);
 | |
| }
 | |
| 
 | |
| int __xray_set_handler_arg1(void (*entry)(int32_t, XRayEntryType, uint64_t)) {
 | |
|   if (!__sanitizer::atomic_load(&XRayInitialized,
 | |
|                                 __sanitizer::memory_order_acquire))
 | |
|     return 0;
 | |
| 
 | |
|   // A relaxed write might not be visible even if the current thread gets
 | |
|   // scheduled on a different CPU/NUMA node.  We need to wait for everyone to
 | |
|   // have this handler installed for consistency of collected data across CPUs.
 | |
|   __sanitizer::atomic_store(&XRayArgLogger, reinterpret_cast<uint64_t>(entry),
 | |
|                             __sanitizer::memory_order_release);
 | |
|   return 1;
 | |
| }
 | |
| 
 | |
| int __xray_remove_handler_arg1() { return __xray_set_handler_arg1(nullptr); }
 | |
| 
 | |
| uintptr_t __xray_function_address(int32_t FuncId) XRAY_NEVER_INSTRUMENT {
 | |
|   __sanitizer::SpinMutexLock Guard(&XRayInstrMapMutex);
 | |
|   if (FuncId <= 0 || static_cast<size_t>(FuncId) > XRayInstrMap.Functions)
 | |
|     return 0;
 | |
|   return XRayInstrMap.SledsIndex[FuncId - 1].Begin->Address
 | |
| // On PPC, function entries are always aligned to 16 bytes. The beginning of a
 | |
| // sled might be a local entry, which is always +8 based on the global entry.
 | |
| // Always return the global entry.
 | |
| #ifdef __PPC__
 | |
|          & ~0xf
 | |
| #endif
 | |
|       ;
 | |
| }
 | |
| 
 | |
| size_t __xray_max_function_id() XRAY_NEVER_INSTRUMENT {
 | |
|   __sanitizer::SpinMutexLock Guard(&XRayInstrMapMutex);
 | |
|   return XRayInstrMap.Functions;
 | |
| }
 |